Product Search
- Type
- Main Terminal
- Interrupted
- Uninterrupted
- Configuration

- Type: DC66P
- Main Terminal: Male Stud
- Interrupted: 80A
- Uninterrupted: 80A
- Configuration: Motor Reversing
- Designed for Direct Current loads and compatible with modern electronic control systems, suitable for use in applications such as battery powered winches, vehicle mounted cranes and small electric vehicles.
- Developed for Interrupted and Uninterrupted applications, and suited for switching Inductive, Resistive and Capacitive loads.
- Monoblock construction and sealed to IP67 offering greater protection against adverse environments such as water or dust and allowing for water immersion up to 1 metre.
- Devised for motor reversing, the main contact circuit has a built in fail safe, so that if both coils are energised simultaneously the contact arrangement is open circuit.
- M6 main stud terminals and 6.3mm spades coil connections.
- Adaptable Mounting options, in any orientation (seek technical advice for full mounting considerations).

- Type: DC88
- Main Terminal: Male/Female Stud
- Interrupted: 100A
- Uninterrupted: 100A
- Configuration: Motor Reversing
- Designed for motor reversing and direct current loads, particularly motors as used on electric vehicles such as industrial trucks.
- Developed for Interrupted and Uninterrupted applications, and suited for switching Inductive, Resistive and Capacitive loads.
- M8 main stud terminals and 6.3mm spades coil connections.
- Adaptable Mounting options, in any orientation (seek technical advice for full mounting considerations).

- Type: DC88-1000P
- Main Terminal: Male Stud
- Interrupted: 100A
- Uninterrupted: 100A
- Configuration: Motor Reversing
- Designed for direct current loads, particularly motors as used on electric vehicles such as industrial trucks.
- Developed for both interrupted and uninterrupted loads, the DC88-1000P Type is suitable for switching Resistive, Capacitive and Inductive loads.
- Monoblock construction and sealed to IP67 offering greater protection against adverse environments such as water or dust, and allowing for water immersion up to 1 metre.
- Devised for motor reversing, the main contact circuit has a built in fail safe, so that if both coils are energised simultaneously the contact arrangement is open circuit.
- M8 stud main terminals and 6.3mm spade coil connections.
- Adaptable Mounting options, in any orientation (seek technical advice for full mounting considerations).

- Type: DC88P
- Main Terminal: Male/Female Stud
- Interrupted: 100A
- Uninterrupted: 100A
- Configuration: Motor Reversing
- Designed for direct current loads, particularly motors as used on electric vehicles such as industrial trucks.
- Developed for both interrupted and uninterrupted loads, the DC88P is suitable for switching Resistive, Capacitive and Inductive loads.
- Sealed to IP66 thus offering greater protection against adverse environments such as water or dust.
- M8 main stud terminals and coil connections are by means of 6.3mm spades.
- Adaptable Mounting options, in any orientation (seek technical advice for full mounting considerations).

- Type: DC92P
- Main Terminal: Male/Female Stud
- Interrupted: 100A
- Uninterrupted: 125A
- Configuration: 2 X NO - SP - ST
- Designed for direct current loads, typical applications include motors as used on electric vehicles such as industrial trucks.
- Developed for both interrupted and uninterrupted loads, the DC92P is suitable for switching Resistive, Capacitive and Inductive loads.
- Devised for motor reversing, the main contact circuit has a built in fail safe, so that if both coils are energised simultaneously the contact arrangement is open circuit
- Monoblock construction and sealed to IP66 thus offering greater protection against adverse environments such as water or dust.
- M8 stud main terminals and 6.3mm spade coil connections.

- Type: DC182
- Main Terminal: Male/Female Stud
- Interrupted: 150A
- Uninterrupted: 150A
- Configuration: Motor Reversing
- Designed for direct current loads, particularly motors as used on electric vehicles such as industrial trucks and airport tractors.
- Developed for both interrupted and uninterrupted loads, the DC182 is suitable for switching Resistive, Capacitive and Inductive loads.
- M8 stud main terminals and 6.3mm spade coil connections.
- Adaptable Mounting options, in any orientation (seek technical advice for full mounting considerations)
View Product
- Type: DC182P
- Main Terminal: Male Stud
- Interrupted: 150A
- Uninterrupted: 150A
- Configuration: Motor Reversing
- Designed for direct current loads, particularly motors as used on electric winches, a monoblock construction it is compatible with modern electronic control systems.
- Developed for both interrupted and uninterrupted loads, the DC88P is suitable for switching Resistive, Capacitive and Inductive loads.
- The main contact circuit, designed for motor reversing, has a built in failsafe, so that if both coils are energised simultaneously the circuit remains open.
- Sealed to IP67 thus offering greater protection against adverse environments such as water or dust.
- M8 main stud terminals and coil connections are by means of 6.3mm spades.
- Adaptable Mounting options, in any orientation (seek technical advice for full mounting considerations).
View Product
- Type: SW60
- Main Terminal: Male Stud
- Interrupted: 80A
- Uninterrupted: 80A
- Configuration: NO - SP - ST
- Designed for Direct Current loads, as used within small traction motors, hydraulic power packs and small electric winch motors.
- Developed for Interrupted and Uninterrupted applications, and suited for switching Inductive, Resistive and Capacitive loads
- M6 stud main terminals and 6.3mm spade coil connections
- Adaptable Mounting options, in any orientation (seek technical advice for full mounting considerations)

- Type: SW66
- Main Terminal: Male Stud
- Interrupted: 80A
- Uninterrupted: 80A
- Configuration: Motor Reversing
- Designed for Direct Current loads and motor reversing, typical applications include small traction motors, hydraulic power packs and small electric winch motors.
- Developed for Interrupted and Uninterrupted applications, and suited for switching Inductive, Resistive and Capacitive loads.
- M6 stud main terminals and 6.3mm spade coil connections.
- Adaptable Mounting options, in any orientation (seek technical advice for full mounting considerations).

- Type: SW88
- Main Terminal: Male Stud
- Interrupted: 100A
- Uninterrupted: 100A
- Configuration: Motor Reversing
- Designed for direct current loads and motor reversing, typical applications include motors as used on electric vehicles such as industrial trucks.
- Developed for both interrupted and uninterrupted loads, the SW88 is suitable for switching Resistive, Capacitive and Inductive loads.
- M8 stud main terminals and 6.3mm spade coil connections.
- Adaptable Mounting options, in any orientation (seek technical advice for full mounting considerations).

- Type: SW182
- Main Terminal: Male Stud
- Interrupted: 150A
- Uninterrupted: 150A
- Configuration: Motor Reversing
- Designed for direct current loads, typical applications include motors as used on electric vehicles such as industrial trucks.
- Developed for both interrupted and uninterrupted loads, the SW88 is suitable for switching Resistive, Capacitive and Inductive loads.
- Devised for motor reversing, the main contact circuit has a built in fail safe, so that if both coils are energised simultaneously the contact arrangement is open circuit.
- M8 stud main terminals and 6.3mm spade coil connections.
- Adaptable Mounting options, in any orientation (seek technical advice for full mounting considerations).
Please note Normally Closed contacts are not suited to make and break load.
View Product
- Type: SW192
- Main Terminal: Male Stud
- Interrupted: 150A
- Uninterrupted: 200A
- Configuration: Motor Reversing
- Designed for direct current loads, typical applications include motors as used on electric vehicles such as industrial trucks.
- Developed for both interrupted and uninterrupted loads, the SW88 is suitable for switching Resistive, Capacitive and Inductive loads.
- Devised for motor reversing, the main contact circuit has a built in fail safe, so that if both coils are energised simultaneously the contact arrangement is open circuit.
- M8 stud main terminals and 6.3mm spade coil connections.
- Adaptable Mounting options, in any orientation (seek technical advice for full mounting considerations).

- Type: SW202
- Main Terminal: Male Stud
- Interrupted: 250A
- Uninterrupted: 250A
- Configuration: Motor Reversing
- Designed for Direct Current loads, originally for motors as used on electric vehicles, such as industrial trucks and airport tractors.
- Developed for both interrupted and uninterrupted loads, the SW202 is suitable for switching Resistive, Capacitive and Inductive loads.
- M10 stud main terminals and 6.3mm spade coil connections.
- Adaptable Mounting options, in any orientation (seek technical advice for full mounting considerations)
Please note Normally Closed contacts are not suited to make and break load.
View Product
- Type: SW688
- Main Terminal: -
- Interrupted: 80A
- Uninterrupted: 80A
- Configuration: Motor Reversing
- Designed for Motor Reversing applications with direct current loads, particularly motors as used on small traction motors, hydraulic power packs and small electric winch motors.
- Developed for both interrupted and uninterrupted loads, the SW688 is suitable for switching Resistive, Capacitive and Inductive loads.
- M6 stud main terminals and 6.3mm spade coil connections.
- Adaptable Mounting options, in any orientation (seek technical advice for full mounting considerations).

- Type: SW688P
- Main Terminal: Male Stud
- Interrupted: 80A
- Uninterrupted: 80A
- Configuration: Motor Reversing
- Designed for Motor Reversing applications with direct current loads, typical applications include motors as used on small traction motors, hydraulic power packs and small electric winch motors.
- Developed for both interrupted and uninterrupted loads, it is suitable for switching Resistive, Capacitive and Inductive loads.
- Incorporates an enclosed top cover and offers environmental protection to IP66.
- M6 stud main terminals and 6.3mm spade coil connections.
- Adaptable Mounting options, in any orientation (seek technical advice for full mounting considerations).

- Type: SW822
- Main Terminal: Male Stud
- Interrupted: 100A
- Uninterrupted: 100A
- Configuration: Motor Reversing
- Designed for direct current loads and motor reversing, typical applications include motors as used on electric vehicles such as industrial trucks and airport tractors.
- Developed for both interrupted and uninterrupted loads, the SW822 is suitable for switching Resistive, Capacitive and Inductive loads.
- M8 stud main terminals and 6.3mm spade coil connections.
- Adaptable Mounting options, in any orientation (seek technical advice for full mounting considerations)

- Type: SW822P
- Main Terminal: Male Stud
- Interrupted: 100A
- Uninterrupted: 100A
- Configuration: Motor Reversing
- Designed for Motor Reversing applications with direct current loads, typical applications include motors as used on electric vehicles such as industrial trucks.
- Developed for both interrupted and uninterrupted loads, it is suitable for switching Resistive, Capacitive and Inductive loads.
- Incorporates an enclosed top cover and offers environmental protection to IP66.
- M8 stud main terminals and 6.3mm spade coil connections.
- Adaptable Mounting options, in any orientation (seek technical advice for full mounting considerations).