Products
Sd200
  • Designed to provide a rapid means of disconnecting batteries or other power supplies in the event of serious electrical faults.
  • Combines the dual function of a manual disconnect and coil operated line contactor.
  • Primarily intended for use with battery powered vehicles, they are also suitable for use with static power systems.
  • Capable of safely rupturing full load battery currents in the event of an emergency.
  • Optionally a Fuseholder for an inline fuse can be provided pre-fitted.  This modification adjusts the positions of the coil terminals and is suitable for ANL or MEGA fuse configurations.

 

The Use of Battery Disconnecting Switches in Electric Vehicles

Modern battery powered electric vehicles are inherently very reliable and safe.  However, even when sophisticated electronic controllers are used it is desirable to have a means of disconnecting the battery in the event of an emergency, such as a vehicle failing to stop or an electrical short circuit.  In many countries it is mandatory to fit one or more devices to achieve an emergency disconnection of the battery.

Precautions:

When fitted with magnetic blowouts the polarity marked on the contact housing must be observed when connecting the main terminals.  Ensure that the switches are installed in a position where heavy arcs emanating from the switch cannot damage or electrically jump across to adjacent parts.  The switch is to be used to rupture current in an emergency or as a no-load isolator.

Do not use as a regular On-Load Switching Device.

Spare Parts are not available – this contactor is deemed non-serviceable.

SD200 Technical Info

Application InterruptedRating (Ith) UninterruptedRating (Ith)
Thermal Current Rating - 200A
Intermittent Current Rating:
30% Duty - 365A
40% Duty - 315A
50% Duty - 285A
60% Duty - 260A
70% Duty - 240A
Rated Fault Current Breaking Capacity (lcn) 5ms Time Constraint: (In accordance with UL583*)
Blowouts 500A at 96V D.C.
No Blowouts 500A at 48V D.C.
Rated Fault Current Breaking Capacity (lcn) Resistive Load: (In accordance with UL508*)
Blowouts -
No Blowouts -
Maximum Recommended Contact Voltages
Blowouts - 96V
No Blowouts - 48V
Typical Voltage Drop per pole across New Contacts at 200A 40mV
Mechanical Durability >3,000,000 Cycles
Coil Voltage Available (Us) (Rectifier board required for A.C.) >6 - 240V

SD200 Features

Click on an optional feature to automatically add this selection to the enquiry form below

ComponentConfigurations
Auxiliary
Blowouts
Coil Suppression
Coil Termination
Contact Tip
Fixed Contact Terminal
Fuse Holder
Magnetic Latching
Manual Override
Mounting
Vacuum Impregnation