RU280P Technical Info
| Application |
InterruptedRating (Ith) |
UninterruptedRating (Ith) |
| Thermal Current Rating |
350A |
350A |
| Intermittent Current Rating: |
| 30% Duty |
640A |
640A |
| 40% Duty |
555A |
555A |
| 50% Duty |
495A |
495A |
| 60% Duty |
450A |
450A |
| 70% Duty |
420A |
420A |
| Rated Fault Current Breaking Capacity (lcn) 5ms Time Constraint: (In accordance with UL583*) |
| Blowouts |
800A at 80V D.C. |
| No Blowouts |
1050A at 48V D.C. |
| Rated Fault Current Breaking Capacity (lcn) Resistive Load: (In accordance with UL508*) |
| Blowouts |
525A at 96V D.C. |
| No Blowouts |
525A at 60V D.C. |
| Maximum Recommended Contact Voltages |
| Blowouts |
96V |
96V |
| No Blowouts |
60V |
60V |
| Typical Voltage Drop per pole across New Contacts at 350A |
40mV |
| Mechanical Durability |
>0 Cycles |
| Coil Voltage Available (Us) (Rectifier board required for A.C.) |
>6 - 240V |
RU280P Features
Click on an optional feature to automatically add this selection to the enquiry form below
RU280P Data Sheet
Format: pdf
Size: 536kb
DOWNLOAD