Spare Parts – Please consult our Technical Department, or download Spare Parts Sheet where available.
TS50 Technical Info
| Application | InterruptedRating (Ith) | UninterruptedRating (Ith) |
|---|---|---|
| Thermal Current Rating | 100A | 600A |
| Intermittent Current Rating: | ||
| 30% Duty | 185A | 1095A |
| 40% Duty | 160A | 950A |
| 50% Duty | 140A | 850A |
| 60% Duty | 130A | 775A |
| 70% Duty | 120A | 715A |
| Rated Fault Current Breaking Capacity (lcn) 5ms Time Constraint: (In accordance with UL583*) | ||
| Blowouts | 500A at 501V D.C. | |
| No Blowouts | 400A at 401V D.C. | |
| Rated Fault Current Breaking Capacity (lcn) Resistive Load: (In accordance with UL508*) | ||
| Blowouts | 200A at 201V D.C. | |
| No Blowouts | 100A at 101V D.C. | |
| Maximum Recommended Contact Voltages | ||
| Blowouts | 200V | 1000V |
| No Blowouts | 2V | 1V |
| Typical Voltage Drop per pole across New Contacts at 23A | 100mV | |
| Mechanical Durability | >10,002 Cycles | |
| Coil Voltage Available (Us) (Rectifier board required for A.C.) | >7 - 112V | |
TS50 Features
Click on an optional feature to automatically add this selection to the enquiry form below
| Component | Configurations |
|---|---|
| Armature Cap | |
| Auxiliary | |
| Blowouts | |
| Coil Economiser | |
| Coil Suppression | |
| Coil Termination | |
| Contact Tip | |
| Mounting | |
| Non Polarity Sensitive | |
| Silver Plating |