SW64P Technical Info
| Application |
InterruptedRating (Ith) |
UninterruptedRating (Ith) |
| Thermal Current Rating |
80A |
80A |
| Intermittent Current Rating: |
| 30% Duty |
145A |
145A |
| 40% Duty |
125A |
125A |
| 50% Duty |
115A |
115A |
| 60% Duty |
105A |
105A |
| 70% Duty |
95A |
95A |
| Rated Fault Current Breaking Capacity (lcn) 5ms Time Constraint: (In accordance with UL583*) |
| Blowouts |
400A at 96V D.C. |
| No Blowouts |
400A at 48V D.C. |
| Rated Fault Current Breaking Capacity (lcn) Resistive Load: (In accordance with UL508*) |
| Blowouts |
120A at 96V D.C. |
| No Blowouts |
120A at 48V D.C. |
| Maximum Recommended Contact Voltages |
| Blowouts |
96V |
96V |
| No Blowouts |
48V |
60V |
| Typical Voltage Drop per pole across New Contacts at 80A |
40mV |
| Mechanical Durability |
>0 Cycles |
| Coil Voltage Available (Us) (Rectifier board required for A.C.) |
>6 - 130V |
SW64P Features
Click on an optional feature to automatically add this selection to the enquiry form below
SW64P-Data-Sheet
Format: pdf
Size: 869kb