- Designed to provide a rapid means of disconnecting batteries or other power supplies in the event of serious electrical faults.
- Combines the dual function of a manual disconnect and coil operated line contactor.
- Primarily intended for use with battery powered vehicles, they are also suitable for use with static power systems.
- All types are capable of safely rupturing full load battery currents in the event of an emergency.
Spare Parts are not available – this contactor is deemed non-serviceable.
SD250 Technical Info
| Application | InterruptedRating (Ith) | UninterruptedRating (Ith) |
|---|---|---|
| Thermal Current Rating | - | 250A |
| Intermittent Current Rating: | ||
| 30% Duty | - | 455A |
| 40% Duty | - | 395A |
| 50% Duty | - | 355A |
| 60% Duty | - | 325A |
| 70% Duty | - | 300A |
| Rated Fault Current Breaking Capacity (lcn) 5ms Time Constraint: (In accordance with UL583*) | ||
| Blowouts | 1000A at 96V D.C. | |
| No Blowouts | 1000A at 48V D.C. | |
| Rated Fault Current Breaking Capacity (lcn) Resistive Load: (In accordance with UL508*) | ||
| Blowouts | - | |
| No Blowouts | - | |
| Maximum Recommended Contact Voltages | ||
| Blowouts | 96V | 96V |
| No Blowouts | - | 48V |
| Typical Voltage Drop per pole across New Contacts at 250A | 30mV | |
| Mechanical Durability | >3,000,000 Cycles | |
| Coil Voltage Available (Us) (Rectifier board required for A.C.) | >6 - 250V | |
SD250 Features
Click on an optional feature to automatically add this selection to the enquiry form below
| Component | Configurations |
|---|---|
| Auxiliary | |
| Blowouts | |
| Coil Suppression | |
| Coil Termination | |
| Contact Tip | |
| Enclosed Top Cover | |
| Fixed Contact Terminal | |
| Lockable | |
| Manual Override | |
| Mounting | |
| Vacuum Impregnation |