Products
  • Designed for direct current loads, particularly motors as used on electric vehicles such as industrial trucks.
  • Developed for both interrupted and uninterrupted loads, the DC88P is suitable for switching Resistive, Capacitive and Inductive loads.
  • Sealed to IP66 thus offering greater protection against adverse environments such as water or dust.
  • M8 main stud terminals and coil connections are by means of 6.3mm spades.
  • Adaptable Mounting options, in any orientation (seek technical advice for full mounting considerations).

Spare Parts are not available – this contactor is deemed non-serviceable.

DC88P Technical Info

Application InterruptedRating (Ith) UninterruptedRating (Ith)
Thermal Current Rating 100A 100A
Intermittent Current Rating:
30% Duty 185A 185A
40% Duty 160A 160A
50% Duty 140A 140A
60% Duty 130A 130A
70% Duty 120A 120A
Rated Fault Current Breaking Capacity (lcn) 5ms Time Constraint: (In accordance with UL583*)
Blowouts -
No Blowouts 800A at 48V D.C.
Rated Fault Current Breaking Capacity (lcn) Resistive Load: (In accordance with UL508*)
Blowouts -
No Blowouts -
Maximum Recommended Contact Voltages
Blowouts - -
No Blowouts 48V 48V
Typical Voltage Drop per pole across New Contacts at 100A 50mV
Mechanical Durability >5,000,000 Cycles
Coil Voltage Available (Us) (Rectifier board required for A.C.) >6 - 240V

DC88P Features

Click on an optional feature to automatically add this selection to the enquiry form below

ComponentConfigurations
Coil Suppression
Coil Termination
Contact Tip
Enclosed Top Cover
Fixed Contact Terminal
IP Rating
Magnetic Latching
Mounting

DC88P-Data-Sheet

Format: pdf
Size: 905kb
DOWNLOAD

Enquiry Form

This site is registered on wpml.org as a development site. Switch to a production site key to remove this banner.